• English
  • Russian
  • English
  • Русский (Russian)
+7 496 216 52 72 aspect@dubna.ru
JSC SPC ASPECT JSC SPC ASPECT
  • About
    • Representatives and partners
    • Licenses and certificates
    • History
    • News
  • Products
  • Service
  • Support
  • Contacts
JSC SPC ASPECT > Products > Laboratory spectrometers > GAMMA-1P

Products

GAMMA-1P

Semiconductor gamma spectrometer.

 

Intended use

The GAMMA-1P laboratory precision gamma semiconductor spectrometer is used for qualitative and quantitative analysis of complex radionuclide samples.

 

Download

  • Leaflet

 

Category: Laboratory spectrometers Tags: Environmental monitoring, Nuclear power industry
  • Description
  • Specifications and Performance
  • Certification

Description

Application

GAMMA-1P is used in laboratories of external dosimetry services, environmental services, radiological laboratories of concerned ministries and departments to check various environmental samples for the presence of gamma-emitting radionuclides, also in radiochemical laboratories to monitor technological processes. The spectrometer can be used in nuclear physics centers for research in various areas of fundamental and applied physics.

Design and operation

GAMMA-1P includes a semiconductor detecting unit, a spectrometric device, a protective lead shield, an operator’s workstation.

The semiconductor detecting unit converts the energy of gamma rays into electrical signals proportional in amplitude for their subsequent processing. The type of the semiconductor detector is selected to meet the customer’s specifications.

The spectrometric device is used to receive spectrometric information from the semiconductor detector. The choice of a specific model of the spectrometric device is determined by the tasks and needs of the customer.

The lead protective shield reduces the level of the external gamma background recorded by the semiconductor detector thus increasing the spectrometer sensitivity. Whereas the most common solution for GAMMA-1P is the Ekran-2P protective shield (stationary floor shield of the original design, lead shield thickness is 82 mm, copper is 1.5 mm, cadmium is 1 mm), other models varying in lead thickness, measuring chamber volume, special features like collimator, are available. For some applications, such as high activity samples, there may be no need for a shield.

The operator’s workstation with installed specialized software allows you to manage accumulation, display, processing of information and output of processing results to external devices. The basic software for GAMMA-1P is SpectraLineGP. SpectraLine Handy or SpectraLine Ultimate can be used instead. NuclideMaster, NuclideMasterPlus, EffMaker are used as additional software that expands the range of tasks to be solved.

GAMMA-1P can come with various accessories: containers and devices for sample measurements, positioning devices, devices for filling the detector with liquid nitrogen, and a desk for equipment.

Features and functional capability

  • The spectrometer composition depends on the tasks, needs and capabilities of the customer
  • Efficiency calibration of the spectrometer is done for a point 5 cm, point 25 cm, and 1 l Marinelli vessel geometries. Calibrations using other laboratory geometries are also possible upon the customer’s request
  • The detector is characterized to correct the radionuclide library for true summation

Specifications and Performance

Range of detected gamma energies

0.05 to 10.0 MeV

Range of measured gamma energies

0.05 to 3.0 MeV

Energy resolution for gamma line with the energy

0.8 keV max (122 keV (Co-57))
1.8 keV max (1332 keV (Co-60))
(typical value, for HPGe detectors)

Minimum measured activity of Cs-137 in a sample with shield application for 1 hour measurement

1.5 Bq max

Relative detection efficiency at the peak of total absorption of gamma quanta for point geometry Co-60 along a line with an energy of 1332 keV, at a source-detector distance of 25 cm

10 % max

Maximum statistical load

5·10⁴ cps min (for SU-05P1)
1·10⁵ cps min (for SU-07CA, SU-07CP)

Integral non-linearity

0.05 % max

Number of channels

8192 (for SU-05P1)
16384 (for SU-07ZA, SU-07ZP)

Confidence limits of activity measurement error (P=0.95)

±(5 to 30) %

Time instability for continuous operation period

±0,1 % max

Operating mode setting time

30 minutes max

Continuous operation

24 hours min

Power supply

~220 V, (50±1) Hz

Environmental

+10 to +35 °С, 75% at +30 °С and lower temperatures without moisture condensation

Certification

Certification

  • GAMMA-1P is registered in the State Register of Measuring Instruments under No. 18392-08
  • GAMMA-1P complies with the requirements for products of safety class 4N according to OPB-88/97
  • GAMMA-1P complies with the Technical Regulations of the Customs Union on safety of low voltage equipment (TR CU 004/2011), Technical Regulations of the Customs Union on electromagnetic compatibility of technical means (TR CU 020/2011)

Measurement procedures

  • Activity of radionuclides in investigated samples. Measurement procedure for gamma spectrometers using the SpectraLine software”. Number in the Federal Information Fund for Ensuring the Uniformity of Measurements is ФР.1.40.2014.18318
  • Procedure for measuring gamma emitting radionuclides in investigated samples using gamma spectrometers with SpectraLine and Nuclide Master Plus software Number in the Federal Information Fund for Ensuring the Uniformity of Measurements is ФР.1.38.2022.43932
  • Procedure for radiation monitoring of metal. Number in the Federal Information Fund for Ensuring the Uniformity of Measurements is ФР.1.40.2020.37618
  • Procedure for measuring the volumetric activity of gamma-emitting radionuclides in samples of aqueous technological media of nuclear power plants and in liquid radioactive waste using GAMMA-1P spectrometers. Number in the Federal Information Fund for Ensuring the Uniformity of Measurements is ФР.1.40.2018.30105. Additional software is required for work with this procedure (Spectran-Gamma)
  • Procedure for measuring the activity of gamma-emitting radionuclides in waste containers using a gamma spectrometric complex with the LSRM SpectraLine and EffMaker software . Number in the Federal Information Fund for Ensuring the Uniformity of Measurements is ФР.1.40.2019.35796

Related products

  • GAMMA-1S

    Laboratory spectrometers
    Read more
  • STU-031

    Technological spectrometric devices
    Read more
  • MKC-A07

    Portable devices
    Read more

JSC SPC ASPECT
8 Sakharova A.D. Street
141980 u.d. Dubna, Dubna
Moscow region, Russia

 

E-mail: aspect@dubna.ru
Phone: +7 496 216-52-72
Fax: +7 496 216-51-08

Company
  • About
    • Representatives and partners
    • Licenses and certificates
    • History
    • News
  • Products
  • Service
  • Support
  • Contacts
Products
  • Radiation monitors
  • Portable devices
  • Personnel contamination monitors
  • Dosimetry equipment
  • Laboratory spectrometers
  • Technological spectrometers
  • Radioactive waste inventory systems
  • Integrated systems
  • Mobile integrated systems
  • Detecting devices and units
  • Nuclear electronics modules
  • Extra equipment and accessories
Search
© 2025 JSC SPC ASPECT
  •   Go to previous website version
  • English
  • Russian

Send request

Contact us by phone, email, or using the feedback form on the website.

+7 496 216 52 72

aspect@dubna.ru

This contact form is available only for logged in users.